th for <register or memory> <name> (data pin = <name>, clock pin = <name>) is <time>


CAUSE: The Timing Analyzer is reporting the specified tH of the specified register with respect to the specified data and clock pins.
ACTION: No action is required. You can click the + icon to expand this message in the Messages window and display the intermediate time increments used to calculate the tH. You can view the results of timing analysis in the Compilation Report.

See also:

Running a Timing Analysis